Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation EAD100 technical sheet

Page 1 of 11100%
Text of this document11 pages · 1,220 words

Page 1

EAD100 ELECTRIC ADVANCE & DROP BRACKET TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

EAD100 ELECTRIC ADVANCE & DROP BRACKET SPECIFICATION MEASUREMENTS Product Dimensions 1155mm [45 1/2"] H x 1600mm [63"] W x 230mm [9 1/16"] D Product Weight 70Kg [154lb] Approximate Screen Sizes 97"+ Maximum Weight Capacity 160Kg [353lb] Max. Depth From Wall 230mm [9 1/16"] Maximum Extension From Wall 883mm [34 3/4 "] Maximum Drop From IN Position 835mm [32 7/8 "] Packaging Dimensions TBC Shipping Weight TBC Advance & Drop Movement Type Motorised Bi-Directional Swivel Movement Type Manual - 20 Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 1500 - 400 W x 800, 600, 500, 400, 300 H Control Options IR Remote, RS232, Contact Closure Product Options / Features Custom mounts / adapters, Custom RAL paint finishes Package Contents Mechanism, IR remote control, Control box Marine Suitable No TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

EAD100 ELECTRIC ADVANCE & DROP BRACKET POSITIONING AND MOVEMENT DETAILS The graph below gives an approximation of Wall Plate position assuming the bottom edge of the screen is 20mm below the wall plate. 32 7/8" max. 835 max. Maximum Drop 13/16" min. 20 min. 2 15/16" 75 731 28 13/16"

Example shown (right) for a 305mm [12"] mantle piece with the EAD100 mounted 75mm [2 15/16"] above it. 28 1/8" R714 If the EAD100 is being recessed then the figure for Mantle Depth increases by the recess depth value. Radius Of Travel 6 5/8" 169 The lower screen edge must sit a minimum of 20mm [13/16"] below the EAD100 wall plate (as shown in views right). If the offset needs to be larger then the wall plate height above mantle increases by the offset amount. 12" 305 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

EAD100 ELECTRIC ADVANCE & DROP BRACKET 6 7/8" 175 1/4" 5.7 MINIMUM SCREEN SIZES A screen with height of 1180mm [46 7/16"] will be required to fully cover the mechanism in the UP position. NOTE: The top of the EAD100 will be visible when in the down position 1180 min. 46 7/16" min.

5 11/16" min. 144 min. 3/16" 7 5/16" 5 185.7 A screen with height of 1360mm [53 9/16"] will be required to fully cover the mechanism in both the UP & DOWN positions.

1360 min. 53 9/16" min.

TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 5 11/16" min. ISSUE 006 144 min. WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

EAD100 ELECTRIC ADVANCE & DROP BRACKET UP POSITION DIMENSIONS 9 1/16" 230 63" 1600 24 9/16" 39 3/8" 624 1000 32 3/4" max. 831.5 max. Screen Mounting 45 7/16" 1154 Height 59 1/16" 15 3/4" 8.5 5/16" Slots 1500.0 400.0 Screen Mounting Width TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

EAD100 ELECTRIC ADVANCE & DROP BRACKET DOWN POSITION DIMENSIONS 8 5/16" 211 19 11/16" 500 47 11/16" 1211 39 3/8" 28" 1000 711 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

EAD100 ELECTRIC ADVANCE & DROP BRACKET SWIVEL DIMENSIONS The EAD100 features a MANUAL swivel that allows the screen to be rotated up to a maximum 20 Left & Right. This Swivel angle will self-centre when the EAD100 is closed. NOTE: The maximum swivel angle is dependant on the screen width. Swivel angle will decrease when used with a deep mantle or recess. Example shown below with a 2400mm [94 1/2"] Wide screen over a 305mm [12"] Deep Mantle. 12" 305 20° max. 94 1/2"

2400

TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

EAD100 ELECTRIC ADVANCE & DROP BRACKET WALL FIXING DIMENSIONS - STEP ONE For installation guidance please refer to the Instruction Documentation. An Installation Wall Plate is provided to hook the mechanism onto, secure this using all 6 Countersunk fixing holes using appropriate fixings (not provided) 6 x 6.6 1/4" Countersunk Holes C L 8 1/2" 215.9 6 1/2" 165.1 2" 50.8 0" 0 0 0"

158.8 158.8 6 1/4" 6 1/4"

TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

EAD100 ELECTRIC ADVANCE & DROP BRACKET WALL FIXING DIMENSIONS - STEP TWO For installation guidance please refer to the Instruction Documentation. Magnetic Covers Once the mechanism is hooked onto the Installation Wall Plate it can be secured through provided to hide ALL 8 holes in the two large wall billets using suitable load bearing fixings (not provided). wall fixings Magnetic Covers are provided to hide wall fixings after installation. 8 x 10.5 7/16" THRU ALL A C L 18 11/16" 2" 475 51 15 9/16" 1 9/16" 395 39 Depth available for wall fixings 12 3/8" 315 7/16" 10.5 1" 25 0" 0 0 0" 159 159 SECTION A-A 6 1/4" 6 1/4" A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

EAD100 ELECTRIC ADVANCE & DROP BRACKET FLUSH RECESS MOUNTING In order to mount a screen flush on the wall on the EAD100, a recess depth of 225mm [8 7/8"] & screen height of minimum 1250mm [49 3/16"] is required. It is recommended the recess depth is greater than mechanism depth to allow for switch adjustment to minimise gap behind screen SECTION B-B SECTION B-B B OUT Position IN Position 3/16" min. 4.8 min. 66 15/16" min. 1700 min. Recess Aperture Width 8 7/8" 225 1250 min. 1230 min. 49 3/16" min. 48 7/16" min. Recess Aperture Height Flush Mounting Screen Height

52 Recess depth 2 1/16" considered as a mantle 1 3/8" to calculate wall plate 35 height positioning. Clearance See Sheet 4 B TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 006 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

EAD100 ELECTRIC ADVANCE & DROP BRACKET POWER SUPPLY UNIT INPUT = 110V (6A) OR 240V (3A) AC MAINS CONTROL BOX OUTPUT = 24V DC, 21A The mechanism Control box must be located in an easily accessible location. 5 7/8" 2 3/16" 149.5 55 CABLE LOOM LENGTH APPROX 118 1/8" 3000 0.79 max20 max

137.5 5 7/16"

MAINS INPUT

286.2 11 1/4" RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE 2 3/16" 6 5/8" 55.1 167.5 PORT IR LEAD INPUT 3.5mm [0.14"] JACK EMERGENCY STOP CONNECTOR NOTES • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 11 FUTUREAUTOMATION

Need assistance or looking to source this item?