This document could not be shown here. Open the PDF.
Text of this document32 pages · 4,121 words
Page 1
CHRT-M / MO MARINE CEILING HINGE RANGE WITH TELESCOPE INSTALLATION INSTRUCTIONS ISSUE 003
Page 3
SAFETY DISCLAIMER IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support four times the weight of the component and any additional apparatus mounted to the component. WARNING: Do not exceed the weight capacity for this product as listed below. This can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated. WARNING: Risk of death or serious injury may occur when children climb on audio and/or video equipment or furniture. A remote control or toys placed on the furnishing may encourage a child to climb on the furnishing and as a result the furnishing may tip over on to the child. WARNING: Risk of death or serious injury may occur. Relocating audio and/or video equipment to furniture not specifically designed to support audio and/or video equipment may result in death or serious injury due to the furnishing collapsing or over turning onto a child or adult. WARNING – RISK OF INJURY! Only for use with equipment weights as specified in technical documentation See specific technical document for weight limits. Use with heavier screens/equipment may lead to instability causing tip over or failure resulting in death or serious injury. Mechanism Suitable for Marine use. ADDITIONAL WARNINGS: 1. Keep all documentation/instructions after fitting. 2. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all documentation is passed on to the end user and read fully before operation. 3. Do not use near water or outdoors unless the product has been specifically designed to do so. 4. Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury. 5. Use this product only for its intended purpose as described in the product instructions and only use attachments/ accessories specified by the manufacturer. 6. Do not operate the product if it is damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Contact the original installer/manufacturer to arrange repair or return. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning. Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. 1
Page 4
PRODUCT WARRANTY & RISK ASSESSMENT WARRANTY INFORMATION WARNING - The warranty offered for this product shall be annulled if the product is used improperly or in a way that is in breach of our Terms of Service. Future Automation provides warranty for the mechanism you purchased for the period of 24 months from the date of purchase, provided that it isn’t used for unintended purposes. Under the warranty, Future Automation aims to either solve the issue remotely (via telephone or email support) or if the mechanism requires a part, arrange a visit to your premises by a Future Automation approved engineer or send replacement items where appropriate. Warranty repairs will be carried out as quickly as possible, but subject to parts availability. This warranty period is respectively extended for the period of a repair. A malfunctioning product must be cleaned and placed into suitable packaging to protect against transit damage before organising delivery to a repair workshop. All the complaints about defects must be submitted to the vendor/installer that sold this product, rather than directly to the manufacturer. Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation. The warranty does not cover the following: • Damages resulting from improper product use or maintenance. • Repairs carried out by unauthorized persons. • Natural wear and tear during operation. • Damages caused by the buyer. • Accidental damages caused by a customer or damages caused as a result of careless attitude or usage, or damages caused by natural disasters (natural phenomena). • Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges etc. • Additional items not supplied by Future Automation although they may have been supplied together by the retailer • Any 3rd party software products controlling your mechanism • Any transfer of ownership. Warranty is provided only to the initial purchaser. • Compensation for loss of use of the product, and consequential loss of any kind. A separate Safety and Servicing Information document is provided with these instructions (additional copies can be found at www.futureautomation.co.uk/safety), and this document MUST be filled out by the approved Future Automation Dealer who is installing the product. This Warranty Sheet must be held by the end user for the duration of the products life and will be referred to during servicing or warranty queries. The Safety and Servicing Information document also contains two Service History Forms that must be filled in by the approved Future Automation dealer who is performing the first required yearly service of this product. One copy of the Service History Form must be held by the customer (along with the Warranty Sheet) and a duplicate copy must be held by the approved Future Automation dealer that performed the service. Missing and/or mismatching documents may delay or invalidate warranty claims. Additional Service History Forms can be found on the Future Automation website for further yearly services. RISK ASSESSMENT INFORMATION It is the installer’s responsibility to perform a risk assessment of installed products. Future Automation can provide guidelines to installers/dealer about what should be included in a risk assessment, but due to the individual nuances of each location/site, Future Automation cannot provide a full list of areas to risk assess. For full risk assessment and safety information please view our Safety and Servicing guide available at www.futureautomation.net/safety 2
Page 5
GUIDE CONTENTS SAFETY DISCLAIMER 1 PRODUCT WARRANTY & RISK ASSESSMENT 2 GUIDE CONTENTS 3 PACKAGE CONTENTS 4 MECHANISM QUICK-START GUIDE 5 INSTALLATION PREPARATION 6 BEAM MOUNTING 7 STUD MOUNTING 8 MARINE OUTDOOR CABLE ROUTING 9 MARINE INDOOR CABLE ROUTING 12 COVERS AND TRIMS REMOVAL 14 MOUNT PLATE REMOVAL 15 TELESCOPE UNIT CABLE ROUTING 16 SCREEN & MOUNT PLATE INSTALLATION 17 GENERAL CONTROL 18 INFRARED (IR) 19 CONTACT CLOSURE 20 RS232 CONTROL 21 HINGING TRAY LEVELLING 22 MOVING TRAY POSITIONING 26 3
Page 6
PACKAGE CONTENTS 1 - CHR MECHANISM 1.1 - MOUNT BRACKETS 2 - INFRARED (IR) REMOTE CONTROL 3 - CHR 17MM ADJUSTMENT SPANNER STANDARD ACCESSORIES (CHR) ACCESSORY PACK: - 2X AAA BATTERIES - MAINS POWER LEAD - INFRARED CONTROL LEAD - CAT5 LEAD WITH RJ45 CONNECTOR - SCREEN FIXINGS PACK (MULTI-PACK OF BOLTS, WASHERS & SPACERS) - FELT PAD 1.1 1 1.1 1.1 2 1.1 3 4
Page 7
MECHANISM QUICK-START GUIDE Some Future Automation mechanisms may ship with the control box disconnected to prevent damage during transit. In order to operate the mechanism, the control box will need to reconnected, then have mains power applied along with the desired control method. RECONNECTING THE CONTROL BOX To reconnect the mechanism control box, follow the below steps: 1. Make sure the power is disconnected from the control box. 2. Remove the retaining screw and washer from the end of the control box to allow removal of the control box lid. (Image 1 Below). 3. Slide off the control box lid to reveal the control board inside. 4. Locate the green connector on the end of the loom leading from the lift mechanism. This plug will have a small tag attached stating the correct connecting socket on the control board (e.g. “AC1”, “DC2”...) (Image 2 Below). 5. Plug the green connector into the corresponding socket on the control board. This plug is handed and will only connect correctly one way. Do NOT force the connector into the socket, this can cause serious damage to the control board and mechanism. 6. Route the wiring loom out of the end of the control box by inserting the black plastic inserts into the slots provided. (Image 3 Below). 7. Slide the control box cover back over the control board and replace the fixing screw and washer. Image 1. Image 2. Image 3. Image 4. IMPORTANT For the mechanism to operate, the green three way safety connector with the loop of wire attached, must also be plugged into the end of the control box. (Image 4 above). If this connector is not plugged in, a bright red LED will be visible inside control board and the Input Confirmation Input LED will be permanently illuminated. 5
Page 8
INSTALLATION PREPARATION The power and IR receiver cables are secured for transit using a red cable 1 tie to the right side of the mechanism. Remove the red cable tie and carefully pull the power and IR cables 2 to full extension ready for installation. With the mechanism laying upside down, operate using IR Controller provided into the OUT position. 3 Check no damage has occured during transit. See Page 19 for futher control information. MOUNTING OPTIONS Option 1 - Beam Mounting Option 2 - Stud Hanging WARNING: CHR MECHANISM DOES NOT HAVE AN ANTI-JAM CAPABILITY. THE MOTOR DRIVE SYSTEM WILL CONTINUE TO MOVE UNTIL A LIMIT SWITCH IS CONTACTED. KEEP HANDS AND ANY OBJECTS CLEAR OF MECHANISM DURING OPERATION TO REDUCE RISK OF DAMAGE OR INJURY. 6
Page 9
ALLOW FOR AV AND POWER CABLES TO ENTER MECHANISM IN SAME LOCATION BEAM AS POWER CORD ON BOTH SIDES. IT MAY BE EASIER TO RUN CABLES MOUNTING BEFORE FINAL FIX INTO POSITION. With the mechanism CLOSED and in the correct orientation (UP AND TV VIEWING AREA IN FRONT OF UNIT) the mechanism can 1 be fixed in the position securely using 4 mounting brackets and suitable fixings (Not Provided). Mechanism mount plates allow up to 12mm [0.5"] diameter fixings to be used. See below for critical dimensions for ceiling structure to allow for easy installation. 2 Dimensional tolerances shown, allow for shims to be used to accurately adjust height. NOTE: Beam width and ceiling opening dimensions can be found on the technical document for the model number mechanism specified. ADDITIONAL STRUCTURE FOR MOUNTING STRUCTURAL CEILING BEAM SUPPLIED MDF PLASTER EDGE TRIMS Supplied MDF Plaster ^ Finished Ceiling Level Edge Trims Ceiling Plasterboard Gyproc Max. 65.0mm [2.6"] This allows for 3mm Min. 65.0mm [2.6"] Plaster Skim To Cover Joint shim which can be Max. 70.0mm [2.8"] changed for finer height adjustment. 7
Page 10
ALLOW FOR AV AND POWER CABLES TO ENTER MECHANISM IN SAME LOCATION STUD AS POWER CORD ON BOTH SIDES. IT MAY BE EASIER TO RUN CABLES MOUNTING BEFORE FINAL FIX INTO POSITION. With the mechanism CLOSED and in the correct orientation (UP AND TV VIEWING AREA IN FRONT 1 OF UNIT) the mechanism can be fixed in the position securely using 4 mounting brackets and suitable fixings (Not Provided). See below for directions for installation and ceiling structure layout to allow for easy installation. 2 NOTE: Stud positions and ceiling opening dimensions can be found on the technical document for the model number mechanism specified. To hang mechanism on studs fixed securely to the ceiling above, suitable fixings should be used (Not Provided). Mechanism mount plates allow up to 12mm [0.5"] diameter fixings to be used and can be rotated 180° for shorter fixings. 8
Page 11
MARINE OUTDOOR CABLE ROUTING CABLES CAN BE ROUTED FROM BOTH SIDES 1 Locate power lead on right side of mechanism secured with red cable tie and attach to wall outlet using compatible power lead (Not Included). 2 Ensuring space is clear below mechanism, operate by sending ‘OUT’ command on IR Remote Control. 3 Route control cables through mechanism and test movement BEFORE installing TV. 9
Page 12
MARINE OUTDOOR CABLE ROUTING CONT. Peel back corner of Front Seal Strip to 4 reveal join in mount strip. Peel back corner of Front Seal Strip to reveal 5 join in mount strip. 10
Page 13
MARINE OUTDOOR CABLE ROUTING CONT. Remove 3 x M5 Countersink Bolts from 6 lower edge of Trim Panel. (3mm Allen Key) Trim panel can be lowered to unhook top edge 7 and moved out of the mechanism, to gain access to the inside of the mechanism to run cables. 11
Page 14
MARINE INDOOR CABLE ROUTING CABLES CAN BE ROUTED FROM BOTH SIDES 1 Locate power lead on right side of mechanism secured with red cable tie and attach to wall outlet using compatible power lead (Not Included). 2 Ensuring space is clear below mechanism, operate by sending ‘OUT’ command on IR Remote Control. 3 Route control cables through mechanism and test movement BEFORE installing TV. 12
Page 15
MARINE INDOOR CABLE ROUTING CONT. Access control panel and wire control 4 panel using image below. 1. 2. 3 x M5 x 12mm CSK bolts 3. 1 2 Control Board Connections (INDOOR ONLY) 1. RS232 (RJ11/RJ25) 2. Contact Closure (RJ45) 3 3. Emergency Stop 4. IR Input 3.5mm Jack 4 13
Page 16
COVERS AND TRIMS REMOVAL 1 3 2 1 Remove / Loosen all retaining bolts holding covers on large top cover. • Loosen 4 x M6 Hex (10mm Spanner) along top edge. • Remove 2 x M5 x 12mm Pozi Machine Screws. • Loosen 1 x M6 Hex (10mm Spanner) on each side. 2 Remove lower front cover. • Remove 2 x M5 x 12mm Pozi Machine Screws. 3 Remove telescopic unit middle cover. • Remove 4 x 45 x 12mm Pozi Machine Screws. 14
Page 17
MOUNT PLATE REMOVAL Locate Mount Plate Lock and 1 turn CCW to release lock. Mount Plate Lock 10mm Spanner/ 3mm Allen Key CW - LOCK CCW - UNLOCK Once unlocked, the mount plate will lift up approximately 20mm [0.8”] and can be pulled 2 forward away from the hinging tray. 3 Display cables can now be routed through the mechanism. 15
Page 18
TELESCOPE UNIT CABLE ROUTING With all cables routed to desired areas of mechanism, panels can be replaced and secured in reverse order of removal. 16
Page 19
SCREEN & MOUNT PLATE INSTALLATION VESA 200 / VESA 300 / VESA 400 COMPATIBLE Suitable for up to M8 Bolts During installation, ensure TV does not overhang edge of moving tray. TV should be no less and 20mm [0.8”] from lower edge of tray. Adjust height of TV on mount plate to suit 1 3 Hook plate on at desired height on tray. Ensure plate is secure and lock plate in place as shown in Mount Plate Removal Section. (4 locating pins will centre plate on tray.) 2 With plate located into side rails, plate will drop down into key shaped slots, apply light pressure to help engage slot. 17
Page 20
GENERAL CONTROL This mechanism has multiple standard control methods, each of which requires a different input method to the control box. For ease, the input sockets on the control board are labelled below. (Control box size and style may vary to image shown) CONTROL BOX INPUTS Marine Indoor Control Board Marine Outdoor Control Board In IP66 Control Box RS232 (RJ11/RJ25) Contact Closure (RJ45) Emergency Stop Connector Input Confirmation LED Mains Voltage Input IR Input Jack (3.5mm) MECHANISM EMERGENCY STOP CONNECTOR This mechanism features an Emergency Stop Connector, which MUST be plugged into the control box in the connector labelled above for the mechanism to operate. If this connector is not plugged in, the Input Confirmation LED will be permanently lit. As per the red plastic tag attached to the Emergency Stop Connector (and shown below), the small loop of wire in this connector is designed to be replaced by a third party safety mechanism. REPLACING MECHANISM BATTERIES The standard Future Automation Infrared (IR) remote control required x2 AAA batteries to operate. These are provided with the mechanism in the Accessories Pack. These batteries can be replaced as the per the image below. 18
Page 21
INFRARED (IR) This Mechanism can be controlled via the supplied 14 button Infrared (IR) Remote Control, pair with the supplied Infrared (IR) lead and sensor. The mechanism's functions can be controlled by plugging the Infrared (IR) lead and sensor into the 3.5mm IR Input Jack shown on the General Mechanism Control page. Confirmation of Infrared (IR) input will be shown by a single flash of the large green LED located on the end of the control box. As Infrared (IR) control works over line of sight, the Infrared (IR) sensor must be directly viewable from what ever location the remote control is being used from. Multi-button commands beginning with STORE should be tapped sequentially within 1 second of each other Infrared (IR) Remote Control Button Layout IN - Brings the mechanism into [STORE] + [OUT] - Stores the the ceiling. maximum travel of the telescope, should a limit be required. OUT - Brings the mechanism out of the ceiling, and extends To utilise this function, press the telescope to the maximum [OUT] and then press [STOP] travel. with the telescope at the desired position. STOP - Will stop the operation of Use the button combination the mechanism at ANY position. above to store this position. [STORE] + [A] - [F] - Stores any To clear the maximum limit to position. (6 positions available) travel further or to full travel, To utilise this feature, press press [STORE], [STOP] and then [OUT] and use [<] and [>] and press [OUT]. [IN] buttons to position hinge, Adjustments can now be made telescope and swivel and press to this position by using [IN] [STOP] at the desired position. and [OUT] to reposition and Use the button combination then repeat the above button above to store this position on combination to relearn. the corresponding button. [STORE] + [STORE] + [HOME] To target stored position press - This carries out a Factory button [A] - [F] that corresponds Reset. This restores control to position required. system to factory defaults, clears all learnt positions and Adjustments can be made to this saved limits. Ensure all limits position by repeating the process HOME - Brings the mechanism are relearnt before normal to reposition and then using the at out of the ceiling and the operation is resumed. above button combination to telescope in the retracted relearn. position. PRESET - Used to independently send DDP (If fitted) to OUT position. IMPORTANT Only buttons indicated above are functional with the product. Any other button press will STOP the mechanism. 19
Page 22
CONTACT CLOSURE This Mechanism can be controlled via Contact Closure, utilising an 8 Pin RJ45 Connector attached to a length of CAT5 (Type 568A or 568B) cable. The mechanism’s functions can be controlled by plugging this into the RJ45 port on the mechanism control board, then shorting pins 1-8 on this connector as shown in the Contact Closure Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box, as well as illumination of the corresponding Contact Closure LED on the printed circuit board as shown below. RJ45 PIN LAYOUT CONTACT CLOSURE LED LAYOUT LED 1 LED 2 LED 3 LED 4 LED 5 (NOT USED) Contact Closure Input Port CONTACT CLOSURE INPUT TABLE WIRE/CABLE TYPE PIN DESCRIPTION ACTION LED 568A 568B INDICATOR 1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED W W G O 2 12V LATCH WHEN 12V ATTACHED, DEVICE WILL MOVE TO PRESET G O POSITION. WHEN 12V REMOVED, DEVICE WILL GO IN. 3 GROUND GROUND W O W G 4 DEVICE LATCH (OUT) SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO OUT B B LED 5 POSITION, WHEN REMOVED DEVICE WILL MOVE TO IN POSITION. 5 DEVICE LATCH SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO W W LED 4 (POSITION ‘A’) POSITION ‘A’, WHEN REMOVED DEVICE WILL MOVE TO IN POSITION. B B 6 DEVICE STOP MOMENTARY SHORT TO GROUND (PIN 3), STOPS DEVICE IN O G LED 3 CURRENT POSITION. 7 DEVICE OUT MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO W W LED 2 OUT POSITION. BR BR 8 DEVICE IN MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO IN BR BR LED 1 POSITION. 20
Page 23
RS232 CONTROL This Mechanism can be controlled via RS232, utilising a 6 Pin RJ11/RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable. The mechanism's functions can be controlled by plugging this into the RJ11/RJ25 port on the mechanism control box, then inputting the RS232 commands shown in the RS232 Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box. RJ11/RJ25 PIN LAYOUT SERIAL PIN LAYOUT PIN 1: TX PIN 2: RX PIN 6: RX PIN 3: TX PIN 3 & 4: GROUND PIN 5: GROUND RS232 PROGRAMMING DETAILS RJ11/RJ25RJ11/RJ25 Func.Func. 9 PIN Serial9 PIN Serial ColourColour Baud Rate: 9600 PIN 1PIN 1 TXTX PIN 2PIN 2 Blue Stop Bit: 1 PIN 3PIN 3 GROUNDGROUND PIN 5PIN 5 Green Parity: None PIN 4PIN 4 GROUNDGROUND PIN 5PIN 5 Red Databits: 8 PIN 6PIN 6 RXRX PIN 3PIN 3 WhiteWhite RS232 INPUT TABLE IMPORTANT - Ensure all protocols are entered exactly as written below, including Carriage Return (ENTER / ASCII 13) Protocol Action fa_in Carriage Return (Enter / ASCII 13) Device IN fa_out Carriage Return (Enter / ASCII 13) Device OUT fa_a Carriage Return (Enter / ASCII 13) - Device OUT to memory position A - F respectively fa_f Carriage Return (Enter / ASCII 13) fa_stop Carriage Return (Enter / ASCII 13) Device STOP (At any position) fa_home Carriage Return (Enter / ASCII 13) Device to HOME (Hinge Down, Telescope Up) position 21
Page 24
HINGING TRAY LEVELLING The moving tray on the mechanism is factory set and should not require any further adjustment after install, however the tray may become misaligned during transit or if removed for maintenance or painting.
Tools required • 4mm Allen Key • 10mm Spanner/ Socket Set • 17mm Spanner (Provided) • Spirit Level or Straight Edge 22
Page 25
HINGE TRAY LEVELLING CONT. 1. Open Mechanism 2. Remove Screen (If Installed) 3. Remove Covers (If Installed) 4. Prepare tools 5. Loosen Clamp Bolts on both sides of tray 5a. 17mm Spanner 5b. Supplied Spanner - Hold Nut - 1/4 Turn Bolt CCW 6. Adjust Height of Tray Using Cam Adjuster 6a. Rotate UP DOWN = 1/2 turn 2.5mm [0.1"] 6b. Rotate DOWN = UP 1/2 turn 2.5mm [0.1"] 23
Page 26
HINGE TRAY LEVELLING CONT. 7. Tighten Clamp Bolts on both sides 7a. 17mm Spanner 7b. Supplied Spanner - Hold Nut - 1/4 Turn Bolt CW 8. Close Mechanism And Check Levels. 9. Reinstall Covers (If Removed) 10. Reinstall TV (If Removed) Repeat steps 5 to 7 if necessary Hinging Tray Positioning Adjustments can be made to the tray position within the ceiling. The CHR is designed to have a 7mm [0.28"] shadow gap at the Front, Left and Right and a 10mm [0.4"] gap at the back. 7mm [0.28"] 7mm [0.28"] 24
Page 27
HINGE TRAY LEVELLING CONT. Adjustments to tray position can be carried out with Screen in place as shown below. Left to Right b. Tools required (10mm Socket / Spanner) a. Loosen 2 M6 Hex Bolts - 1 turn b. Move tray as needed c .Tighten 2 M6 Hex Bolts - 1 turn a. c. 25
Page 28
MOVING TRAY POSITIONING Front to Back UP - CW / CW Tools required (4mm Allen Wrench / Key) Rotate socket on each side as needed. 1 CW Turn = 1mm Up 1 CCW Turn = 1mm Down DOWN - CCW / CCW 26
Page 29
NOTES:
Page 30
NOTES:
Page 32
EUROPEAN OFFICE NORTH AMERICAN OFFICE Address: Address: Unit 6-8 Enterprise Park Brunel Road 127 Venture Drive Bedford Dover Bedfordshire NH MK41 9TG 03820 Phone: +44 (0) 1438 833577 Phone: +1 (603) 742 9181 Email: info@futureautomation.co.uk Email: info@futureautomation.net OfÏce Hours: OfÏce Hours: Mon - Fri 8:00 to 17:30 GMT Mon - Fri 7:00 to 17:00 EST Saturday & Sunday - Closed Saturday & Sunday - Closed www.FUTUREAUTOMATION.net
Need assistance or looking to source this item?