Rako WP-CON Instruction Manual

Page 1 of 3100%
Text of this document3 pages · 348 words

Page 1

Rako Controls Ltd

USING WP-CON WITH RAKO WIRED SYSTEM

WP-CON is used to connect accessory modules to RAKO Wired system. These include RF-Bridge, 232-Bridge, DMX unit and other RAKO modules fitted with RJ11 network connector. Often the accessories are plugged directly into RAK-Link or Star-Wiring Box. WP-CON is used if installation requires the accessory module to be located elsewhere.

A SIMPLE INSTALLATION. 230v ac

bles a In this system Wallplate 1 c K4 and RAKLink are at end of A l R CAT5 cable so need 45 ternaJ Termination Jumpers fitted InR Lighting Circuits

Cat5 data cable

RAKLink

WP-CON 1 Wallplate 1 WP-CON 2 Wallplate 2 Figure 1

Accessory Accessory Module Module

Figure 1 shows a simple lighting installation using the Rako Wired system.

In figure 1: WP-CON 1 and the RAKLink are at each end of the cable, so these must have their termination jumpers fitted. WP-CON 2 and Wallplates 1 & 2 must not have termination jumpers fitted. WP-CON.doc Page 1 of 3 Issue A. March 2010

Page 2

Rako Controls Ltd

Installing WP-CON onto the Wired System

Items required:

Circuit boards Assembly Cover Plate & Fixing Kit Tools (not included)

Figure 2

Fit the WP-CON as shown in figure 3 below: Fitting WP-CON to Back box Backbox minimum 25mm deep Strip outer insulation from CAT5 cable SET THE TERMINATION JUMPERS Follow the colour coding written on the circuit board Fit the mounting frame Screw on the face plate Figure 3 WP-CON.doc Page 2 of 3 Issue A. March 2010

Page 3

Rako Controls Ltd

Fit Termination Jumpers to WP-CON when it is fitted at end of Data Network

UNTERM WP-CON which is not at end Figure 4 of line set like this. TERMINATION (WP-CON2 in figure 1) JUMPERS ON WP-CON NOTE: Devices are normally supplied unterminated with jumpers in this position TERM WP-CON which is at end of line set like this. (WP-CON1 in figure 1) STAR TERM This setting used only if a RAKO STAR WIRING box is fitted to the system. See Star Box User Manual for details WP-CON.doc Page 3 of 3 Issue A. March 2010