Instruction Manual RLED75CV1 1 Channel Constant Voltage Dimmer 2024 Version 2.0.0

Page 2

For more information relating to the RLED75CV1 see the Wireless Module Application Sheet , Wireless RAK Application Sheet, and Wireless Device LED Diagnostics . For programming a wireless system, including the device in this manual: Wireless Module Programming Guide Contents 1. What is the RLED75CV1? 2. Loadings 3. Installation 4. Initial Checks 5. Programming the RLED75CV1 6. Appendix 1: LED Diagnostics 7. Appendix 2: Wiring Example 1 What is the RLED75CV1? The RLED75CV1 is a Wireless single Channel constant voltage dimmer designed for constant voltage LED loads. With its built-in receiver, the RLED75CV1 works with a Rako Wireless system and a Rako Wired* system. The RLED75CV1 can be programmed from an RCM keypad, or via Rasoft Pro using a programming tool (RAMPI or HUB). Ceiling installation or surface mount installation is available for the RLED75CV1. For surface mount installation, a bracket is provided. *requires a WK-HUB in range of the RLED75CV1 2 Loadings Maximum Load at 12V DC 75W Maximum Load at 24V DC 150W NB Loads should be tested before being connected to the RLED75CV1. RLED75CV1 Manual Version 2.0.0

Page 3

3 Installation of the RLED75CV1 Installation should only be carried out by a competent electrician. Do not connect directly to a 230V supply. RLED75CV1 modules should be mounted in areas which are adequately ventilated, dry, and outside of any enclosed metal casings that may interfere with the Wireless signal. Modules should be mounted vertically, with the terminals at the bottom, or horizontally, with ventilation slots at the front. Do not obstruct the ventilation slots. While the modules are designed to be completely maintenance-free, they should be mounted in an accessible location should investigation or re-addressing be necessary. Step 1 Remove the cover and the cable clamp. Step 2 Connect the DC power supply to the ‘IN’ terminals of the RLED75CV1 as well as the load cable to the ‘OUT’ terminals. Step 3 Replace the cable clamp, and ensure that the cables are held firmly in place. Step 4 Replace the cover. RLED75CV1 Manual Version 2.0.0

Page 4

4 Initial Checks When the module powers up, the load should dim up to full brightness. The clear button can be used as a manual on/off switch. The internal LED behind the clear button will flicker when the module receives any Rako Wireless message and is a useful diagnostic indicator. This function becomes inactive after 20 minutes to avoid a nuisance light spill but can be re-activated by pressing the clear button. 5 Programming the RLED75CV1 Once the RLED75CV1 has powered up and has been tested working with the setup button, the device is ready to be programmed. For instructions on how to program the RLED75CV1, see the Wireless Module Setup Guide . RLED75CV1 Manual Version 2.0.0

Page 5

6 Appendix 1: LED Diagnostics Wireless Range LED Pulses Description Good Wireless reception When the unit is receiving successfully, there will be four rapid pulses on the LED when any Wireless message is sent. Bad Wireless reception When the unit is out of range, there will be intermittent pulses on the LED when any Wireless message is sent. NB It is recommended to install a Wireless repeater (WRB-100) if you are experiencing intermittent Wireless range. 7 Appendix 2: Wiring Example The diagram below shows an example of how the RLED is to be connected. Please check with the power supply manufacturer for compatibility before installing it with an RLED product. RLED75CV1 Manual Version 2.0.0