This document could not be shown here. Open the PDF.
Text of this document6 pages · 565 words
Page 1
Instruction Manual RMT-1200 1200W Trailing Edge Wireless Dimmer
2025 Version 2.0.1
Page 2
Contents 1.0 What is the RMT-1200? 3 2.0 Loadings 3 3.0 Installation of the RMT-1200 3 4.0 Initial Checks 5 5.0 Programming the RMT-1200 5 6.0 Appendix 1: LED Diagnostics 6
RMT-1200 Instruction Manual | Page 2 Manual Version 2.0.1
Page 3
1.0 What is the RMT-1200?
The RMT-1200 is a trailing edge dimming module designed for mains dimmable LED’s and trailing edge dimmable loads.
RMT-1200 dimmers are not suitable for inductive loads such as wire-wound transformers or electric motors. 2.0 Loadings Minimum 1W Maximum 1200W
Low-voltage transformer 1080W (de-rate by 10%) loads Mains voltage LEDs 600W (de-rate by 50%)
3.0 Installation of the RMT-1200
Installation should only be carried out by a competent electrician.
RMT-1200 modules should be mounted in adequately dry and ventilated areas outside of any enclosed metal casings that may interfere with the wireless signal.
Modules should be mounted vertically, with the terminals at the bottom.
Ensure that cable clamps are securely fitted on the supply and load cables.
While the modules are designed to be completely maintenance-free, they should be mounted in an accessible location should investigation or re-addressing of the units be necessary.
RMT-1200 Instruction Manual | Page 3 Manual Version 2.0.1
Page 4
Remove the cover by 1 removing the two screws at the bottom of the unit, pulling the bottom of the cover away from the bottom, and lifting it up.
Insert the supply IN cables 2 as well as the load OUT cables.
Fit the supplied cable 3 clamps and ensure the cables are unable to move.
Replace the cover and 4 replace the screws.
RMT-1200 Instruction Manual | Page 4 Manual Version 2.0.1
Page 5
4.0 Initial Checks When power is initially connected to the module, the load should power up to full brightness.
The button on the top right of the unit can be used to put the device into set-up mode as well as to toggle the load on and off for testing purposes.
The LED on the circuit board flashes four times when the module receives any Rako Wireless message, and it is a useful diagnostic indicator. This function becomes inactive after 20 minutes to avoid a nuisance light spill but can be reactivated by pressing the setup button. For more information on LED diagnostics, see 6.0 Appendix 1: LED Diagnostics.
5.0 Programming the RMT-1200
Once the RMT-1200 has powered up and has been tested with the setup button, the device is ready to be programmed.
Programming using a RAMPI or HUB Wireless System Setup Guide
Programming using an RCM Keypad Programming With An RCM Guide.
For further general information relating to the RMT-1200, see the Wireless Module Application Sheet.
RMT-1200 Instruction Manual | Page 5 Manual Version 2.0.1
Page 6
6.0 Appendix 1: LED Diagnostics
Wireless Range LED Pulses Description Good wireless reception When the unit is receiving successfully, there will be four rapid pulses on the
LED when any wireless message is sent. Bad wireless reception When the unit is out of range, there will be intermittent pulses on the
LED when any wireless message is sent.
NB It is recommended to install a wireless repeater (WRB-100) if you are experiencing intermittent wireless range. Should the module not respond to any of the above, check the supply voltage.
For additional diagnostic information, see the Wireless Device LED Diagnostics
RMT-1200 Instruction Manual | Page 6 Manual Version 2.0.1
Need assistance or looking to source this item?