Lutron – Wired PIR Ceiling Occupancy Sensor – LOS2-CIR

The LOS2-CIR is a wired PIR ceiling occupancy sensor for use with Energi Savr Node modules, available in white or black. Its 360° view can be masked off in parts, and buttons on the front set the timeout and sensitivity. It wires to a module's sensor input, or to a QSM3-4W-C sensor module.

Supplied as part of a Lutron systemThe LOS2-CIR-XX is part of a Lutron system that must be designed, installed and commissioned by a Lutron certified engineer. Contact our design and engineering team for a quotation.Contact our team for a quotation

Quantity

Specification

Additional information

Manufacturer

Lutron

Range

Energi Savr Node

Model

LOS2-CIR-XX

Product Type

Sensors

Finish

White (WH) or black (BL), in place of XX in the code

Sensor type

Wired passive infrared (PIR) ceiling sensor. XCT technology detects major, minor and fine motion

Works with

Energi Savr Node units with sensor inputs: four inputs, each powering one sensor. QS sensor modules (QSM): four inputs, powering up to 12 sensors, three per input

Field of view

360°. Parts of the lens can be masked off to stop the sensor seeing hallways or next-door spaces

Settings

Timeout 1, 5, 8, 15 (default), 20 or 30 minutes; 1 and 8 minutes by advanced button presses. PIR sensitivity high (default), medium, low or minimum

Ambient light detection

Stops the lights turning on when there is enough natural light. Adjustable threshold, off by default

Power

15–24 V DC, IEC PELV / NEC Class 2, 16 mA maximum

Control output

15–24 V DC active-high logic signal with short-circuit protection; open collector when unoccupied

Dimensions

102 mm diameter, 33 mm deep

Mounting

Ceiling tile, through a 21 mm hole with the threaded post, retainer and locknut; or other ceilings and fixtures on the twist-lock mounting plate

Environment

0–40 °C. Relative humidity less than 95%, non-condensing. Indoor use only

Regulatory approvals

CE / UKCA, IEC, RoHS compliant

Replaces

Direct replacement for LOS-CIR sensors

Specification Sheets & Documents

PDF · opens in a new tab

Not sure it’s the right part?

Speak to our in-house specialists about your system, we’ll help identify the part you need.

Similar Products

Lutron QSE-CI-WCI wallbox closure interface, drawing from Lutron’s specification sheet
Refurbished
New, Box Opened

Lutron HomeWorks – QSE-CI-WCI Wallbox Closure Interface – QSE-CI-WCI

Lutron LOS2-CIR-R-XX, drawing from Lutron’s documents
Refurbished
New, Box Opened

Lutron – Wired PIR Ceiling Occupancy Sensor with Relay – LOS2-CIR-R

Lutron Energi Savr Node QSNE-4A5-230-D, drawing from Lutron’s specification sheet
Refurbished
New, Box Opened

Lutron Energi Savr Node – PRO LED+ Phase Adaptive Power Module – QSNE-4A5-230-D

Lutron HomeWorks QSX Contact Closure Interface QSE-IO
Refurbished
New, Box Opened

Lutron HomeWorks – QSE-IO Contact Closure Interface – QSE-IO